Orthopedic Implants Trauma Plate Distal Radius Multi-Axial Locking Plate

Jiangsu Gather Biotech Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Orthopedic Implants Trauma Plate Distal Radius Multi-Axial Locking Plate

  • 1
  • 2
  • 3

Brand Name : Gather

Model Number : 11.06.0224.008113

Certification : CE/ISO

Place of Origin : Jiangsu ,China

MOQ : 1

Payment Terms : L/C, T/T, , D/A, Western Union

Supply Ability : 6000pc/month

Delivery Time : 5-15 work days

Packaging Details : Non sterilized , PE bag , carton package

Price : $38-50

Material : Titanium,Stainless Steel/Titanium,Titanium&Stainless Steel,Titanium & Stainless Steel

Type : Implantation Equipments,orthopedic implant,Furniture Lock

Properties : Implant Materials & Artificial Organs

Licence number : CE/ISO13485,ISO

Application : Trauma Operation,Fracture,Distal Radius Medial Locking Plate,Suitable for fractures of the proximal end of the humerus,Fractures & Osteotomies

Product name : LCP Plate,orthopedic implants,trauma implant

Usage : Orthopedic Surgery,Surgical Room,For fixing fractures,Orthopedic Implant,Proximal humerus or fractures of the humerus

Transportation : FedEx. DHL.TNT.EMS.etc,DHL/FEDEX/TNT/EMS

Oem : Accepted,Available

Packing : PE BAG/cartons packing outside

Name : Tibial Narrow locking plate,5.0 straight narrow locking plates of orthopaedic implants,locking plate system instrument set

Contact Now

Orthopedic Implants Trauma Plate Distal Radius Multi-Axial Locking Plate

The treatment of distal radius fractures requires a meticulous reconstruction of the joint surface, as well as stable internal fixation and early functional postoperative treatment.
Extra-articular fractures require both the restoration of the volar tilt and radial length to reduce the possibility of displacement. Malalignment may result in limitations of movement, changes of load distribution, and midcarpal instability, as well as increased risk of osteoarthritis in the radiocarpal joint. Intra-articular fractures with articular displacement of more than 2 mm in the radiocarpal joint may result in osteoarthritis and functional impairment.
The distal radius and distal ulna form a three-column biomechanical construction3:


• The intermediate column is the medial part of the distal radius, with the lunate fossa and the sigmoid notch.
• The radial column is the lateral radius with the scaphoid fossa and the styloid process.
• The ulnar column is the distal ulna, the triangular fibrocartilage, and the distal radioulnar joint.
Following reduction, stabilization requires optimal fixation of the intermediate column as well as the radial column. In the case of a fractured distal ulna that compromises the distal radioulnar joint, the ulnar column should be stabilized as well.

Orthopedic Implants Trauma Plate Distal Radius Multi-Axial Locking Plate

Orthopedic Implants Trauma Plate Distal Radius Multi-Axial Locking Plate

Product No. Specification Length * Width * Thickness Material
1201-A1002(L/R) 2 Holes 51*8*2.2 Pure Titanium
1201-A1003(L/R) 3 Holes 59*8*2.2
1201-A1004(L/R) 4 Holes 67*8*2.2
1201-A1005(L/R) 5 Holes 75*8*2.2

Product Tags:

Distal Radius Multi-Axial Locking Plate

      

Orthopedic Implants Trauma Plate

      

Orthopedic Surgery Locking Plate

      
Wholesale Orthopedic Implants Trauma Plate Distal Radius Multi-Axial Locking Plate from china suppliers

Orthopedic Implants Trauma Plate Distal Radius Multi-Axial Locking Plate Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Jiangsu Gather Biotech Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0